Advanced Optical Technologies

Precision engineering for everyone.

Arkametrix designs and manufactures optical control technologies — galvanometer scanner systems, the control electronics that drive them, and the integration that makes them work inside your machine.

6000 mm/s
Marking speed
< 8 µrad
Repeatability, RMS
± 12.5°
Mechanical scan angle
What we do

Optical hardware, control systems, and the engineering that connects them.

Arkametrix works across the full stack — optics, electronics, control and software — so a system arrives as one designed solution rather than a set of sourced parts.

Galvo Scanner Systems

Precision laser scanning and beam positioning systems engineered for speed, accuracy and reliability.

Custom Control Systems

Intelligent control solutions designed around your specific machine, process and automation requirements.

Optical-Electrical Systems

Integrated optical and electrical technologies developed to bring advanced applications from concept to production.

System Integration

End-to-end integration of hardware, electronics, controls and software for coherent system performance.

After-Sales Services

Responsive technical support and lifecycle services that keep systems performing reliably long after installation.

01 / Automatic calibration

Optical closed-loop calibration

0.999
Scan field linearity

An integrated laser and optical calibration system maintains scan field accuracy in place, rather than depending on a single factory calibration held at the point of manufacture.

02 / Thermal management

Additively manufactured cooling

< 15 µrad
Zero drift per °C

Cooling channels are printed within the scanner body, dissipating heat from the motors and optical components so the scan field remains stable through extended operation.

03 / Multi-laser architecture

Single integrated head plate

1 : 4
Plates to scanner heads

Dual- and quad-head configurations mount to one machined plate. Every head shares the same mechanical datum, minimising head-to-head alignment error at installation.

Our products

Vision Systems — the galvanometer scanner platform.

One platform, three configurations. Every Vision Systems scanner shares the same calibration, cooling and mounting architecture, so moving from a single laser to four does not mean re-engineering the machine around it.

Model
Scanner heads
Laser channels
Mounting reference
VS1
1
1
Single scanner head
Single-axis configuration for one laser channel.
VS2
2
2
Single integrated head plate
Dual-head configuration sharing one machined mounting plate.
VS4
4
4
Single integrated head plate
Quad-head configuration sharing one machined mounting plate.
The Arkametrix position

Accuracy is not something you certify once. It is something you hold.

A scanner starts leaving calibration the moment it starts working. Motors warm. Optics drift. Mounting planes move under load. The industry answers this with a factory certificate and a service interval. Vision Systems answers it with three decisions taken inside the machine — so the field you commissioned is the field you are still running in month eighteen.

Industries we serve

Built for applications where accuracy is not negotiable.

Additive Manufacturing
Aerospace
Medical Technology
Advanced Manufacturing
Research Institutions
OEMs and Machine Builders
Applications

Where Vision Systems is used.

The same platform, configured against the constraint that actually governs the process — build-plate size, cycle time, feature tolerance or beam stability.

01

Laser powder bed fusion

Multi-laser scan heads on a shared reference plane for large-format metal additive manufacturing.

Governing constraint: head-to-head stitching accuracy across the build plate.
02

Laser marking and engraving

High-speed beam positioning with repeatable field accuracy across long production runs.

Governing constraint: field accuracy held across an unbroken shift.
03

Micro-machining

Fine-feature processing where field linearity and thermal stability determine achievable tolerance.

Governing constraint: linearity at the edge of the field, not just the centre.
04

Laser welding

Controlled beam delivery for precision joining in aerospace and medical assemblies.

Governing constraint: repeatable energy placement on a moving seam.
05

Scientific instrumentation

Beam steering and optical control for laboratory and research systems.

Governing constraint: drift over long unattended acquisitions.
06

Spectroscopy

Optical control assemblies developed for analytical and measurement applications.

Governing constraint: positional repeatability between successive scans.
How we work

An engineering process, not a catalogue.

01

Application review

We start from the laser source, field size, cycle time and integration constraints — not from a catalogue part number.

You receive: a written statement of the constraints we are designing against.
02

System specification

Configuration, optics and control architecture are defined against your application and issued as a written specification.

You receive: the specification sheet and mounting drawings for sign-off.
03

In-house build

Additive manufacture, optical assembly, control electronics and firmware are produced under one roof, on an internal supply chain.

You receive: the built system with its measured calibration record.
04

Integration and support

Commissioning, calibration and lifecycle service, with development and serviceability designed in from the first drawing.

You receive: commissioning on your machine and a named engineering contact.
About Arkametrix

An engineering company, first.

Arkametrix Solutions was founded by Shivaprasad DV and Bhanushree Sridhar Balaram, bringing together more than fifteen years of combined experience across advanced electrical engineering, biomedical technologies and additive manufacturing.

The company was built on a straightforward belief: the technologies that power advanced manufacturing should be accessible to the industries that need them — not only to the few manufacturers large enough to specify them from abroad.

Optics, electronics, control and software sit in one building in Bengaluru. That is a deliberate choice rather than a convenience: it is what allows a change in the optical design to be answered in the firmware the same week, and it is why commissioning and service are handled by the people who designed the system.

In-house
Design and manufacture
Bengaluru
Design, build and service
Four disciplines
Optics, electronics, controls, software
Optical mirror assembly photographed under blue laboratory illumination
Specification

The Vision Systems specification sheet.

Full mechanical, optical and control specifications for VS1, VS2 and VS4 — written for the engineer who has to fit this into an existing machine.

Issued by our engineering team, usually within one working day.
01

Mechanical and optical data

Scan angles, aperture options, repeatability and marking speed for all three configurations.

02

Interface and mounting

Control protocol, connector pinouts and mounting drawings with datum references.

03

Operating envelope

Thermal, duty-cycle and environmental limits, with the conditions each figure was measured under.

Tell us about your application.

Send the laser configuration, field size and cycle requirement. Our engineering team will confirm the appropriate Vision Systems configuration and issue the corresponding specification.

Arkametrix Solutions — Bengaluru, India
© 2026 Arkametrix Solutions
Privacy · Terms · Cookies